GRAPPA Acceleration Factors on Sagittal T2 Lumbar MRI Image Quality in Clinical Hernia Nucleus Pulposus
DOI:
https://doi.org/10.36590/jika.v6i3.951Keywords:
acceleration factor, lumbar MRI, image qualityAbstract
Hernia Nucleus Pulposus (HNP) is the most common cause of back pain in the elderly. The most sensitive imaging to see HNP is using MRI. MRI examinations that are a little long can cause patient discomfort, especially with clinical HNP, because patients will complain of pain located in the lower back and result in suboptimal MRI images, therefore requiring a relatively faster scan time, thus requiring the GRAPPA Parallel Imaging technique which can produce good image quality with a short scanning time. The purpose of this study was to compare the GRAPPA factor acceleration value and to determine the correlation between image quality and the use of different GRAPPA factor accelerations. This study used 10 samples of patients with clinical Hernia nucleus pulposus MRI T2 Sagittal FSE examination at Indriati Solo Baru Hospital using the GRAPPA Acceleration Factor value. The results of the GRAPPA technique images on each sample were assessed for image quality quantitatively based on the SNR value and scan time. Based on the SNR value results, Acceleration Factor 1 has a higher average value compared to Acceleration Factor 2 and 3, while Scantime Acceleration Factor 2 has a shorter scanning time compared to Acceleration Factor 1 and 3. The GRAPPA technique can be applied to produce good image quality with fast scanning time.
Downloads
References
Abraham D, Nishimura M, Cao X, Liao C, Setsompop K. 2023. Implicit Representation of Grappa Kernels for Fast Mri Reconstruction. Cornell University, 1: 1-24. https://arxiv.org/abs/2310.10823
Aja-Fernández S, Ferrero VS, Vega AT. 2014. Noise Estimation in Parallel MRI: GRAPPA and SENSE. Magnetic Resonance Imaging, 32(3): 281-290. https://doi.org/10.1016/j.mri.2013.12.001.
Bagus MYB, Darmini D, Mulyati S. 2020. Analisis Perbedaan Kualitas Citra dan Informasi Anatomi pada Pemeriksaan MRI Lumbal Sekuen T2wi Fast Spin Echo (FSE) Potongan Sagital dengan Variasi Nilai Time Repetition. Jurnal Radiografer Indonesia, 3(1): 5-12. Https://Doi.Org/10.55451/Jri.V3i1.53
Basit A, Inam O, Omer H. 2023. Accelerating GRAPPA Reconstruction Using SoC Design for Real-Time Cardiac MRI. Computers in Biology and Medicine, 160: 1-5. https://doi.org/https://doi.org/10.1016/j.compbiomed.2023.107008.
Cummings E, Macdonald, JA, Seiberlich N. 2022. Chapter 6 - Parallel Imaging. Advances in Magnetic Resonance Technology and Applications, 7: 129-157. Https://Doi.Org/Https://Doi.Org/10.1016/B978-0-12-822726-8.00016-6.
Hamilton J, Franson D, Seiberlich N. 2017. Recent Advances in Parallel Imaging for MRI. Progress in Nuclear Magnetic Resonance Spectroscopy, 101: 71-95. Https://Doi.Org/10.1016/J.Pnmrs.2017.04.002.
Ikhsanawati A, Tiksnadi B, Soenggono A, Hidajat NN. 2015. Herniated Nucleus Pulposus in Dr. Hasan Sadikin General Hospital Bandung Indonesia. Althea Medical Journal, 2(2): 179-185. Https://Doi.Org/10.15850/Amj.V2n2.568.
Knoll F, Hammernik K, Zhang C, Moeller S, Pock T, Sodickson DK, Akcakaya M. 2020. Deep-Learning Methods for Parallel Magnetic Resonance Imaging Reconstruction: A Survey of The Current Approaches, Trends, and Issues. IEEE Signal Processing Magazine, 37(1): 128-140. Https://Doi.Org/10.1109/Msp.2019.2950640
Nguyen KTK, Hien MN. 2019. A Comparison Study of Grappa and Generalized Series Methods for Parallel MRI at High Acceleration Factor. [Prosiding]. 2019 Asia-Pacific Signal and Information Processing Association Annual Summit and Conference, Apsipa. Https://Doi.Org/10.1109/Apsipaasc47483.2019.9023117.
Nikoli? O, Nikoli? MB, Pantelic M, Till V, Stojanovic S, Molnar U. 2025. Compressed Sense Acceleration Factor Influence on Magnetic Resonance Image Quality in Patients with Endometrial Cancer. European Journal Of Medical Physics, 130: 1-15. Https://Doi.Org/Https://Doi.Org/10.1016/J.Ejmp.2025.104899
Radhakrishna CG, Vignaud A, Bertrait M, Massire A, Bottlaender M, Ciuciu P. 2025. Bringing Grappa to Non-Cartesian MRI Through Sparkling: An Application to Mprage Anatomical MRI. Hal Science Ouverte, 1-8. https://hal.science/hal-04885977v1
Runge VM, Nitz WR, Trelles M, Goerner FL. 2014. The Physics of Clinical Mr Taught Through Images. India: Thieme Publisher.
Sheng J, Wang B, Ma Y, Liu Q, Liu W, Chen B, Shao M. 2019. Improved Parallel Mr Imaging with Accurate Coil Sensitivity Estimation Using Iterative Adaptive Support. Biomedical Signal Processing and Control. Biomedical Signal Processing and Control, 51: 73-81. Https://Doi.Org/10.1016/J.Bspc.2019.02.001.
Xu L, Zheng Q, Jiang T. 2018. Improved Parallel Magnertic Resonance Imaging Reconstruction with Complex Proximal Support Vector Regression. Scientific Reports, 8(1): 1-9. Https://Doi.Org/10.1038/S41598-018-33171-X.
Yanasak N, Chair T, Clarke. G., Chair Ft, Stafford Rj, Goerner F, Steckner M, Bercha I, Och J, Amurao M. 2015. Parallel Imaging in MRI: Technology, Applications, and Quality Control. American Association of Physicists in Medicine, 118: 1-43. https://www.aapm.org/pubs/reports/RPT_118.pdf
Yanasak NE, Kelly MJ. 2014. Mr Imaging Artifacts and Parallel Imaging Techniques with Calibration Scanning: A New Twist on Old Problems. Radiographics, 34(2): 532-548. Https://Doi.Org/10.1148/Rg.342135051.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Danu Alief Pandoyo, Eunike Serfina Fajarini, Muhaimin

This work is licensed under a Creative Commons Attribution 4.0 International License.

